Author-submitted data information
ID | 210 |
Title | Imaging underground resistivity structure and checking the fit between observed and calculated data |
Creator | Zhiguo An |
Subject | Data files of CSAMT and MT |
Publisher | Xiukuan Zhao |
Description | In June 2017 we carried out data acquisition with Phoenix V8 and MTU equipment, which are widely used in the world. The study area is located in Taohemu super-large silver-polymetallic deposit, Inner Mongolia. The dataset includes CSAMT and MT data of two survey lines. |
Contributor | Zhiguo An |
Date | June 2017 |
Type | L1-CSAMT.dat The resistivity model of Line1 based on CSAMT scalar data. The file consists of three columns, namely distance, depth and resistivity.
L1-CSAMT-Pseu-section.dat The fit of CSAMT observed and calculated data of Line 1. The file consists of six columns, namely distance, log(frequency), log(observed resistivity), log(calculated resistivity), observed impendence phase and calculated impendence phase. L1-MT-Pseu-section.dat The fit of MT observed and calculated data of Line 1. The file consists of six columns, namely distance, log(frequency), log(observed resistivity), log(calculated resistivity), observed impendence phase and calculated impendence phase. L1-TM-MT.xyz The resistivity model of Line 1 based on MT data of TM mode. Apart from the fourth column, the file consists of three columns, namely distance, depth and resistivity. L2-CSAMT.dat The resistivity model of Line2 based on CSAMT scalar data. The file consists of three columns, namely distance, depth and resistivity. L2-CSAMT-Pseu-section.dat The fit of CSAMT observed and calculated data of Line 2. The file consists of six columns, namely distance, log(frequency), log(observed resistivity), log(calculated resistivity), observed impendence phase and calculated impendence phase. L2-MT-Pseu-section.dat The fit of MT observed and calculated data of Line 2. The file consists of six columns, namely distance, log(frequency), log(observed resistivity), log(calculated resistivity), observed impendence phase and calculated impendence phase. L2-TM-MT.xyz The resistivity model of Line 2 based on MT data of TM mode. Apart from the fourth column, the file consists of three columns, namely distance, depth and resistivity. |
Format | .dat, .xyz available in notebook |
URL | http://www.geophys.ac.cn/ArticleData/20200727ResistivityByAn.zip |
DOI | 10.12197/2020GA011 |
Source | |
Language | eng |
Relation | |
Coverage | |
Rights | Institute of Geology and Geophysics, Chinese Academy of Sciences |